Flow cytometry (FC) is a method for characterizing the counts and size distribution of particles, such as blood cells, in a fluid, . The original technique passed cells through pores in a membrane and measured the current produced; this was the Coulter Counter of 1953. Prior to this invention, blood cell counting was a laborious and variable manual procedure. [1] In current laboratory medicine, it primarily is a laser-based fluorescence detection method used to characterize cell antigens on large numbers of hematopoetic or lymphoid cells in suspension typically derived from peripheral blood, bone marrow aspirate or lymph node tissue.[2]

Laser-based flow cytometry instruments use a thin laminar flow of fluid to direct thousands of cells from a small diameter nozzle through a thin beam of laser light of a certain wavelength. The cells are categorized by size forward light scatter, cellular complexity or granularity side scatter.[3] They may also measure the fluorescence of antigen-coupled dyes with which the cells have been treated, as with fluorescence intensity for each 'CD' clusters of differentiation marker. The antigen distribution for thousands of cells is printed in graphical histograms which a pathologist interprets individually and collectively to determine the phenotype of dominant cell populations in leukemias and lymphomas[4] of various types.

Current advances

Today's flow cytometers are considerably more advanced than the simple cell sorters of early times. For example, some are equiped with a dozen or more, even 18, detectors that selectively detect different fluorescent dyes. Although many dozens of dyes are available, some of the more popularly used dyes include Cy3, Cy3.5, Cy5, Cy5.5, flourescein and FITC. When using appropriately dye-labeled antibodies or aptamers to selectively bind to a subset of particles or cells, a population of particles can be seperated and quantified. Typical high end flow cytometers can sort 100,000 particles in about a minute. By using very small electric fields, the cytometers can deflect the flowing particles into a number of different particle containers, thus sorting them, based on the relative side scattering versus the forward scattering. When detecting labeled binding agents on the particles, the ratio of side scattering to forward scattering is used to normalize for differential particle sizes. Although dyes typically have a narrow maximum emission spectrum, they always emit at other lower frequencies, which necessitates that the arrangement of detectors must be optimized to reduce cross-talk between dyes, such as between an orange dye and a red dye.

References

  1. Wallace H. Coulter (1913-1998): Automated Blood Analysis, Inventor of the Week
  2. Flow Cytometry, Division of Laboratory Medicine, University of Washington
  3. Harris, William V.; Land, Bruce R. (August 1978), Cell size measurements using light in flow cytometry and cell sorting, United States Patent 4765737
  4. A.Bruce Lyons and Christopher R. Parisha (2 May 1994), "(Abstract) Determination of lymphocyte division by flow cytometry", Journal of Immunological Methods 171 (1): 131-137, DOI:10.1016/0022-1759(94)90236-4