Spectrum bias: Difference between revisions

From Citizendium
Jump to navigation Jump to search
imported>Aleksander Stos
m (needs some more work to be qualified cz_live;)
imported>Aleksander Stos
m (Internal Article=> CZ_Live)
Line 14: Line 14:


[[Category:Health Sciences Workgroup]]
[[Category:Health Sciences Workgroup]]
[[Category:CZ Live]]

Revision as of 15:45, 30 June 2007

Initially identified in 1978[1], spectrum bias is a common flaw in studies of diagnostic tests in which the control group is comprised of people who are certainly disease-free and the test group is comprised of people known to have the disease. This leads to an overestimation of the sensitivity and specificity of the test.[1][2] Examples are initial overestimates of the sensitivity and specificity of the carcinoembryonic antigen[3] and urinary dipstick tests.[4]

In such instances, the sample is biased to particular areas of the spectrum of disease (disease free, slightly diseased, moderately diseased, extremely diseased), namely the disease free and extremely diseased. While diagnostic tests among such populations may appear to be highly specific and sensitive, when used on the population at large, they could in fact miss patients who are only mildly ill or early in the stages of the disease's progression.

If properly analyzed, recognition of heterogeneity of subgroups can lead to insights about the test's performance in varying populations.[5]

References

  1. 1.0 1.1 Ransohoff DF, Feinstein AR (1978). "Problems of spectrum and bias in evaluating the efficacy of diagnostic tests". N. Engl. J. Med. 299 (17): 926-30. PMID 692598. PMID 692598[e]
  2. Goehring C, Perrier A, Morabia A (2004). "Spectrum bias: a quantitative and graphical analysis of the variability of medical diagnostic test performance". Statistics in medicine 23 (1): 125-35. DOI:10.1002/sim.1591. PMID 14695644. PMID 14695644. Research Blogging.
  3. Fletcher RH (1986). "Carcinoembryonic antigen". Ann. Intern. Med. 104 (1): 66-73. PMID 3510056. PMID 3510056[e]
  4. Lachs MS, Nachamkin I, Edelstein PH, Goldman J, Feinstein AR, Schwartz JS (1992). "Spectrum bias in the evaluation of diagnostic tests: lessons from the rapid dipstick test for urinary tract infection". Ann. Intern. Med. 117 (2): 135-40. PMID 1605428. PMID 1605428[e]
  5. Mulherin SA, Miller WC (2002). "Spectrum bias or spectrum effect? Subgroup variation in diagnostic test evaluation". Ann. Intern. Med. 137 (7): 598-602. PMID 12353947. PMID 12353947[e]

See also